Brand Compatibility Hub

Verify instant pinout, mold matching, and clinical form factors across 12+ international bedside monitor brands.

Real-Time Pinout Verification Active
Sample Lookups:
Verified Match for: M1191B
Adult Reusable Soft Silicone SpO2 Sensor, 12-pin
Medke Equivalent: P8119B (100% In Stock & Cleared)
Philips Healthcare
Philips HealthcareNetherlands
Covered Monitor Series & Modules8 Core Series
IntelliVue MX400-MX800IntelliVue MP20-MP90Avalon Fetal SeriesEfficia CM10-CM150SureSigns VM/VSHeartStart MRx/XL+M1205A / M1008BX2 / X3 Transport
Signal Benchmark: 0-Signal Drift Verified
D-Sub 8-pin, 12-pin, Dual-pin fast snap. ±0.02mm pinout tolerance. Zero signal drift.
Clinical CategoryInterface SpecificationMolds OpenedStatus
SpO2 Sensors
D-Sub 8-pin / 12-pin Direct & Adapter42 Molds100% In Stock & Cleared
ECG & EKG Cables
12-pin Trunk & 3/5/10-Lead AHA/IEC36 Molds100% In Stock & Cleared
NIBP Cuffs & Hoses
Quick-Lock Snap Coupler (Zero-Leak)28 Molds100% In Stock & Cleared
IBP Transducer Kits
12-pin Round Connector (BB-103)16 Molds100% In Stock & Cleared
Temperature Probes
2-pin Round YSI 400 Series Compatible14 Molds100% In Stock & Cleared

Core Clinical Form & Spec Matrix

Physical form factors, patient weight bands, conductor metallurgy, and regulatory clearances spanning Medke's 5 monitoring product categories.

Disposable Sensors

Single-Patient Use
  • Weight Bands & Sites4 Classes
    Adult (>40kg, index finger), Pediatric (10-50kg), Infant (3-20kg, great toe), Neonate (<3kg, foot sole/palm).
  • Adhesive Foam SubstrateClosed-Cell PE
    Micro-porous hypoallergenic acrylic adhesive with total optical light barrier preventing phototherapy interference.
  • Velcro Sponge WrapNICU Gentle
    Non-adhesive gentle polyurethane sponge with adjustable Velcro tab designed for fragile, skin-breakdown prone neonates.
  • Specialty Forehead PatchLow Perfusion
    Supraorbital artery site sensor delivering stable plethysmographic signals during severe peripheral vasoconstriction.

Reusable Sensors

8 Clinical Forms
  • P9 & P7 Hard ClipsABS Medical Shell
    P9 Adult Hard Clip and P7 Pediatric Hard Clip with calibrated stainless steel hinge springs and ergonomic finger grip pads.
  • P8 & P6 Soft Tips100% LSR Silicone
    P8 Adult and P6 Pediatric liquid silicone rubber boots with biocompatible non-latex contact and pressure-sore prevention.
  • P5 & P4 Flexible FormsNeonate / Y-Type
    P5 Neonate silicone wrap with locking strap; P4 Multi-site Y-sensor with convertible silicone tie / ear clip attachments.
  • P3 Ear & PA VeterinarySpecialty Clamps
    P3 Adult high-sensitivity earlobe clip; PA Veterinary lingual/ear clip with dual spring tension for clinical animal care.

Adapter Cables

Dual-Shielded TPU
  • Cable Length Matrix1.0m / 2.4m / 3.0m
    Precision-engineered extension cords with low-attenuation tinned copper conductors and Kevlar tensile reinforcement.
  • Shielding Metallurgy>98% Braided Coverage
    Double-layer foil plus tinned copper braided mesh shielding protecting high-gain photodiode currents from 50/60Hz noise.
  • Mechanical Reliability>50,000 Flex Cycles
    Strain relief boots molded with medical Santoprene elastomer withstanding severe 90-degree oscillatory bending stress.
  • Connector Plating30μ Gold Plating
    Micro-polished gold-plated phosphor bronze terminal pins ensuring insertion life exceeding 5,000 mating cycles.

Patient Terminations

5 Terminal Types
  • 4.0mm Snap SocketStandard Stud
    High-retention beryllium copper spring mechanism ensuring solid snap engagement with all ANSI/AAMI disposable electrodes.
  • Grabber / Pinch MechanismSurgical Claw
    Spring-loaded clamp jaw delivering constant 120g gripping force without slipping during intense patient mobilization.
  • Dual-Purpose ClampSnap + Tab Hybrid
    Universal hybrid clamp head seamlessly accommodating both round snap studs and flat disposable electrode tabs.
  • Banana & DIN 42802Gold Lantern Petals
    4.0mm Banana plug with resilient gold lantern springs (<0.2Ω contact resistance) and 3.0mm DIN needle sockets per DIN 42802.

Cable Systems

Defib Proof
  • One-Piece Direct Cables3 & 5-Lead Molded
    Hermetically ultrasonic welded junction yolk blocks preventing chemical ingress during high-level disinfection wipe-downs.
  • Trunk & Detachable Leads3/5/6/10/12-Lead
    Modular trunk architecture with low-insertion-force multi-pin yolk connectors for cost-effective single-lead replacement.
  • Defibrillation ResistorsBuilt-in 10kΩ
    Precision 10kΩ current-limiting protection resistors integrated into leadwire hubs to protect patients from RF electrosurgical burns.
  • Diagnostic EKG & Holter10-Lead Resting
    Diagnostic 10-lead cables for resting electrocardiographs and ultra-flexible lightweight leads for 24-48h Holter recorders.

Color & Standards

AHA & IEC Dual
  • AHA (AAMI) StandardUS / Americas
    White (RA), Black (LA), Red (LL), Green (RL), Brown (V1-V6) with permanent laser-etched anatomical text marking.
  • IEC StandardEurope / International
    Red (R), Yellow (L), Green (F), Black (N), White (C1-C6) ensuring zero cross-connection error in global ICU environments.
  • Noise Suppression JacketCarbon-Coated
    Semi-conductive carbon layer surrounding core copper strands, eliminating triboelectric noise generated by patient movement.
  • Dielectric Voltage Withstand5,000V Dielectric
    High-voltage defibrillation withstand rating up to 5,000V DC per ANSI/AAMI EC53 without dielectric breakdown.

Disposable Neonatal

Sizes 1# to 5#
  • 5-Color Coding System3.0cm to 15.0cm
    1# (3.1-5.7cm, Orange), 2# (4.3-8.0cm, Teal), 3# (5.8-10.9cm, Green), 4# (7.1-13.1cm, Navy), 5# (8.5-15.0cm, White).
  • Ultrasonic TPU WeldingSeamless Edge
    Medical pure TPU bladder ultrasonically fused with soft non-woven fabric. 100% Latex-free and DEHP-free biocompatibility.
  • Index & Range MarkersFail-Safe Guide
    High-contrast arterial line and arm circumference range markings ensuring accurate oscillometric pulse detection.
  • Lumen ConfigurationsSingle & Dual Tube
    Available in both single-lumen micro luer and dual-lumen barb connectors for compatibility with neonatal bedside monitors.

Reusable Cuffs

Infant to Thigh 66cm
  • C6 Bladderless SeriesAntimicrobial PU
    Integrated one-piece coated polyurethane cuff with no internal bladder. Fully submersible in bleach and quaternary ammonium.
  • C1/C2 Nylon SeriesRemovable Bladder
    High-denier abrasion-resistant woven nylon outer casing with durable pull-out TPU internal air chamber.
  • Burst Pressure Rating≥600 mmHg
    Ultrasonic welded perimeter seams withstand over 600 mmHg inflation pressure without rupture (exceeds ISO 81060-1).
  • Velcro Fatigue Life>10,000 Cycles
    Industrial-grade hook-and-loop fastening system maintaining >85% retention strength after 10,000 repeated cycles.

Connectors & Hoses

FDA K242623
  • Pneumatic Quick Couplers30+ Molds
    Precision brass nickel-plated and medical POM couplers compatible with Philips snap, GE screw-lock, Mindray push, Colin.
  • Zero-Leakage Sealing<1 mmHg / min
    Automated pressure-decay decay testing ensures leak rate <1.0 mmHg over 5 minutes under 300 mmHg static pressure.
  • Reinforced TPU HosesKink-Resistant
    1.5m, 2.5m, and 3.0m heavy-wall medical polyurethane hoses resisting compression and pulse signal dampening.
  • FDA 510(k) ClearanceK242623 Approved
    Officially cleared under FDA 510(k) K242623 for adult, pediatric, and neonatal hospital blood pressure measurement.

Disposable Transducers

BB-101 to BB-105
  • Platform Line Compatibility5 Industry Standards
    BB-101 (Abbott/Medex), BB-102 (Edwards Lifesciences), BB-103 (Philips/B.Braun), BB-104 (BD), BB-105 (Utah Medical).
  • Silicon Piezoresistive Chip5.0 µV/V/mmHg ±1%
    Solid-state micro-machined piezoresistive silicon bridge delivering ultra-linear physiological pressure conversion.
  • Measurement Range-50 to +300 mmHg
    Broad dynamic pressure range (-6.6 to +40 kPa) supporting arterial (ART), central venous (CVP), and pulmonary wedge (PAWP).
  • Sterile PresentationEO Sterile Pack
    Individually packaged in medical Tyvek peel pouches, Ethylene Oxide (EO) sterilized with 3-year verified shelf life.

Dual Flush Architecture

3 ml/h Continuous
  • Continuous Micro-Flush3.0 ± 1 ml/h
    Precision ceramic flow restrictor maintaining continuous 3ml/h heparinized saline infusion to prevent catheter lumen occlusion.
  • Fast Flush ValveHigh Flow Rapid
    Ergonomic pull/squeeze silicone flush valve enabling instantaneous fast flushing and dynamic square-wave response verification.
  • Fluid Channel TransparencyOptical Clear PC
    Crystal-clear medical polycarbonate housing with zero dead-space geometry ensuring rapid, bubble-free priming.
  • Stopcocks & TubingNon-Compliant
    Includes color-coded 3-way stopcocks and high-durometer non-compliant pressure monitoring lines preventing pulse wave damping.

Interface Cables

40+ Host Pinouts
  • Monitor Host Direct Plugs40+ Monitor Models
    Compatible interface cables for Philips 12-pin, GE 11-pin, Mindray 12-pin, Dräger 7-pin, Nihon Kohden 14-pin, Spacelabs.
  • ESU Noise RejectionDouble Metal Braid
    High-coverage tinned copper double braid effectively shielding sensitive 5μV signals against electrosurgical cutting noise.
  • Zero Drift Baseline<1 mmHg / 8h
    Ultra-stable thermal compensation circuitry maintaining baseline pressure drift <1.0 mmHg throughout 24-hour ICU monitoring.
  • Cable Jacket DurabilityMedical Polyurethane
    Highly flexible, halogen-free medical TPU jacket resistant to alcohol, betadine, and enzymatic disinfectant detergents.

Reusable Probes

IPX7 Immersion Proof
  • Skin Surface Probeφ9.8mm Flat Disc
    Mirror-polished medical 316L stainless steel flat disc delivering high thermal conductivity and rapid response time (τ ≤ 2.5s).
  • Body Cavity Probeφ4.0mm / φ3.0mm
    Seamless rounded bullet tip in Adult (φ4.0mm) and Pediatric (φ3.0mm) calibers for non-traumatic esophageal and rectal monitoring.
  • IPX7 Waterproof SealingLiquid Disinfectable
    Hermetically epoxy-encapsulated sensor head fully compliant with IPX7 immersion requirements for glutaraldehyde soaking.
  • Strain Relief Construction>1,000 Wipe Cycles
    Reinforced flex boots molded with medical Santoprene elastomer preventing core wire fracture at the sensor transition point.

Disposable Probes

Single-Patient Clinical
  • Skin Radiant Heat PatchReflective Aluminum
    Mylar-backed reflective aluminum foil foam patch reflecting ambient operating room lighting and radiant warmer heat.
  • Depth-Marked Cavity ProbeGraduated Markings
    Clear centimeter graduations (5cm to 30cm) along the medical PVC sheath for precise anatomical depth placement.
  • Esophageal StethoscopeAudio + Temperature
    Combined acoustic diaphragm and core temperature thermistor enabling continuous cardiopulmonary auscultation during surgery.
  • Foley Catheter IntegrationBladder Temperature
    Temperature-sensing Foley catheter adapters providing continuous urinary bladder core body temperature monitoring in the ICU.

Standards & Clearances

FDA K243000
  • YSI 400 & 700 Dual Standard2252Ω & Dual NTC
    Compatible with YSI 400 series (2252Ω at 25°C) and YSI 700 series dual thermistor bridge monitors.
  • Clinical Accuracy±0.1°C (25°C-45°C)
    Calibrated precision conforming strictly to ISO 80601-2-56 across the critical physiological range 25.0°C to 45.0°C.
  • FDA 510(k) ClearanceK243000 Approved
    Officially cleared under FDA 510(k) K243000 for continuous human temperature monitoring in operating rooms and ICUs.
  • Biocompatibility TestingISO 10993 Passed
    Passed rigorous ISO 10993 cytotoxicity, intracutaneous irritation, and delayed-type hypersensitivity safety certifications.

3-Step Biomedical Engineering Protocol

How hospital clinical engineers verify replacement cable compatibility before procurement or trial deployment.

1

Inspect Physical Port & Host Model Plate

Locate the monitor front-end module or side-panel jack label. Note connector outer diameter and internal polarizing ridge orientation.

2

Verify Anti-Mismatch Keyway Notch & Pin Count

Match pin geometry against Medke engineering CAD drawings. Our molds feature proprietary keyway notches ensuring zero socket forcing.

3

Request Pre-Production Sample or Pinout Dossier

Evaluate functional samples with 100% factory dielectric inspection reports and ISO 10993 biological safety certificates.

Hotline: contact@medke.comInquire Technical Support →
Engineering Authority Resource · 2026 Edition

Medke Master Cross-Reference Handbook (472+ Models)

Instant access to our comprehensive engineering matrix containing exact OEM part numbers, pinout wiring diagrams, mold tolerances, and distributor pricing brackets.

Complete lookup index for Philips, GE, Mindray, Dräger, Masimo & Nihon Kohden
High-resolution vector pinout diagrams with internal resistor & shield layouts
Tiered factory direct pricing schedules for hospital contractors and distributors
Direct download link released immediately after work email verification.

Zero Signal Drift & Mechanical Integrity Guarantee

Engineered to deliver electrical parameter parity with original factory cables while safeguarding clinical monitor receptacles.

Zero Signal Drift Parity

Impedance-matched coaxial cores eliminate waveform attenuation, baseline wander, and electrosurgical unit (ESU) radiofrequency artifacts.

±0.02mm Pin Mating Tolerance

Precision beryllium copper and phosphor bronze contact pins prevent mechanical socket stretching and gold-finger abrasion.

ISO 10993 Biocompatibility

Medical-grade thermoplastic elastomer (TPE) and TPU jackets certified for cytotoxicity, sensitization, and clinical disinfectant wipes.

1,500V Dielectric Tested

100% high-voltage dielectric insulation tested before packaging, guarding patients and monitors against electrical discharge.

Intellectual Property & Compatibility Notice: All OEM product names, model designations, connector identifiers, and trademarks (including Philips, GE Healthcare, Mindray, Dräger, Spacelabs, Welch Allyn, Masimo, Nellcor, Nihon Kohden, Edwards Lifesciences, etc.) displayed on this page remain the proprietary property of their respective manufacturers. Medke products are aftermarket compatible medical accessories independently engineered to match or exceed OEM physical and electrical specifications; they are not manufactured by or affiliated with original equipment manufacturers.

Working with an unlisted or obsolete monitor port?

Our mold development laboratory houses over 1,500 historical connector dies dating back to 2008. If your clinical device is out of production or unlisted above, send us a photograph of the connector port for immediate engineering cross-match within 2.4 hours.

3D Reverse Pinout Analysis
7-14 Day Rapid Prototype Tooling
100-Unit Low-Volume Batch

Direct Engineering Verification

Snap a clear photo of the side-panel port or existing damaged cable connector:

WhatsApp Photo to Engineer (+86 153 0265 4212)Email Blueprint to contact@medke.com
Compatibility Vault Status
WhatsApp